beautypg.com

Appendix c: specifications of digital module, Appendix c: specifications of digital module -4 – RIGOL DG5000 Series User Manual

Page 220

background image

RIGOL

Chapter 14 Appendix

User’s Guide for DG5000

14-4

Appendix C: Specifications of Digital Module


Unless otherwise noted, all the specifications are applicable to the digital modules of
DG5000 series function/arbitrary waveform generator. All the specifications can be
guaranteed if the following two conditions are met.

 The generator has been working continuously for 30 minutes at specified

temperature.

 Open the system function menu and execute “Test Calibration” if the operating

temperature is equal to or more than 5℃.

Common Specifications
Digital Voltage Range

1.4~4.2V (Typical value and user-defined value) (except RS232)

Trigger Mode

Auto trigger and burst trigger

Code Pattern

ALL_0, ALL_1, 01, PRBS, User

User Space

256k Bytes in-line editing, 2M Bytes output (PC editing)

Parameters and Specifications relating to PO Protocol
Analog Voltage Range

1.4~9.4V

Clock (CLK) Line

C0 and C1 (selectable)

Clock Phase

0

0

, 90

0

, 180

0

, 270

0

(adjustable)

Data Line

D0~D15 (selectable)

Transmission Rate

1bps~100Mbps (adjustable)

Output Data Range

1Byte~128k Bytes (selectable)

Mask Channel Setting

None, D0~D15 (selectable)

Tri-state Channel Setting

None, D0~D15 (selectable)

Parameters and Specifications relating to IIC Protocol
Analog Voltage Range

1.4~9.4V

Bit Order

MSB

Clock (CLK) Line

D0~D15 (selectable)

Data Line

D0~D15 (selectable)

Transmission Rate

1bps~15Mbps (adjustable)

Output Data Range

1Byte~10k Bytes (selectable)

Output Address (selectable) None or 7bits address
Operation Mode

When selecting address output, select read or write mode

Parameters and Specifications relating to SPI Protocol