beautypg.com

Protocol setting, Protocol setting -30 – RIGOL DG5000 Series User Manual

Page 180

background image

RIGOL

Chapter 10 Advanced Operation

User’s Guide for DG5000

10-30

Protocol Setting


Press Config to open the protocol setting menu. For different protocols, different
parameters are to be set.

1. RS232 Protocol Setting

When “RS232” protocol is currently selected, press Config to open the
corresponding setting menu.

 Press #Data to set the transmission data length per frame to 5bits, 6bits,

7bits or 8bits.


Note, if the “#Data” set is less than 1byte (8bit), the most significant bit is
dropped in the output. For example, when “#Data” is set to 7bits, the 0 (in bold)
is not output when outputting the data 0x08 (00001000).

 Press Verify to set the verification mode to None, Odd, Even, Fixed0 (the

“verify” bit is always set to 0) or Fixed1 (the “verify” bit is always set to 1).

 Press StopBit to select 1bit, 1.5bits or 2bits.
 Press BaudRate to set the data transmission rate (in bps) to 2400, 4800,

9600, 19.2k, 38.4k, 57.6k, 115.2k or User. When “User” is selected, use the
knob or number keypad to input the desired rate and the range available is
from 1bps to 60Mbps.



2. SPI Protocol Setting

When “SPI” protocol is currently selected, press Config to open the
corresponding setting menu.

 Press CPOL to select 0 or 1, wherein, 0 represents negative polarity and 1

represents positive polarity.

 Press CPHA to select 0 or 1, wherein, 0 represents 0° and 1 represents 180°.
 Press #Data to select 1Byte, 2Byte or 3Byte.


Note, data per frame (#Data) is limited by the current output data length (refer to
To Set the Output Data Length”). For example, when the output length is
1Byte, the #Data menu cannot be set to 2Byte or 3Byte.

 Press Rate and use the knob or number keypad to input the desired rate and