4.2.6 Encoder Output Pulse Setting

4-12

4.2.6 Encoder Output Pulse Setting

Set the encoder output pulse using the following parameter.

Pulses from the encoder per revolution are divided inside the SERVOPACK by the number set in this parame-

ter before being output. Set according to the system specifications of the machine or host controller.

According to the encoder resolution, the number of encoder output pulses are limited. Set the encoder output

pulses (Pn212) by the following setting unit.

Note 1. The setting range varies with the encoder resolution for the servomotor used.

An encoder output pulse setting error (A.041) will occur if the setting is outside the allowable range or does not
satisfy the setting conditions.
Pn212 = 25000 (P/Rev) is accepted, but
Pn212 = 25001 (P/Rev) is not accepted. The alarm A.041 is output because the setting unit differs from that in
the above table.

2. The upper limit of the pulse frequency is approx. 1.6 Mpps.

The servomotor speed is limited if the setting value of the encoder output pulses (Pn212) is large.
An overspeed of encoder output pulse rate alarm (A.511) will occur if the motor speed exceeds the upper limit
specified in the above table.

Output Example: When Pn212 = 16 (16-pulse output per one revolution), PAO and PBO are output as shown

below.

Pn212

Encoder Output Pulses

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

16 to 1073741824

1 P/Rev

2048

After restart

Setup

Speed

Position

Torque

Setting Range of

Encoder Output

Pulses

(P/Rev)

Setting Unit

(pulse)

Encoder Resolution

Upper Limit of Servomotor Speed for

Set Encoder Output Pulses

(min

-1

)

13 bits

(8,192

pulses)

17 bits

(131,072

pulses)

20 bits

(1,048,576

pulses)

16 to 2048

1

6000

16 to 16384

1

6000

16386 to 32768

2

3000

32772 to 65536

4

1500

65544 to 131072

8

750

131088 to 262144

16

375

Preset value: 16

1 revolution

PAO

PBO

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16