2 monitor modes – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual
Page 319
10 Appendix
10-22
10.2 Monitor Modes
The following list shows monitor modes available.
Un Number
Content of Display
Unit
Un000
Motor rotating speed
min
-1
Un001
Speed reference (for speed control)
min
-1
Un002
Internal torque reference ( in percentage to the rated torque)
%
Un003
Electrical angle 1
pulse (encoder resolution)
Un004
Electrical angle 2
deg
Un005
Input signal monitor
−
Un006
Output signal monitor
−
Un007
Reference speed (for position control)
min
-1
Un008
Position error amount (for position control)
reference unit
Un009
Accumulated load ratio (in percentage to the rated torque:
effective torque in cycle of 10 seconds)
%
Un00A
Regenerative load ratio (in percentage to the processable
regenerative power: regenerative power consumption in cycle
of 10 seconds)
%
Un00B
Power consumed by DB resistance
(in percentage to the processable power at DB activation: dis-
play in cycle of 10 seconds)
%
Un00C
Reference counter
reference unit
Un00D
Feedback pulse counter
pulse (encoder resolution)
Un00E
Fully-closed feedback pulse counter
pulse (encoder resolution)
Un012
Total operation time
100 ms
Un013
Feedback pulse counter
reference unit
Un014
Effective gain monitor (gain setting 1 = 1, gain setting 2 = 2)
−
Un015
Safety I/O signal monitor
−
Un020
Motor rated rotational speed
min
-1
Un021
Motor maximum rotational speed
min
-1