Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual
Page 133

4 Operation
4.6.2 External Device Monitor (EDM1)
4-50
(1) Connection Example and Specifications of EDM1 Output Signal
Connection example and specifications of EDM1 output signal are explained below.
Connection Example
EDM1 output signal is used for source circuit.
Specifications
Electrical characteristics of EDM1 signal are as follows.
For safety function signal connections, the input signal is the 0V common and the output
signal is the source output. This is opposite to other signals described in this manual. To
avoid confusion, the ON and OFF status of signals for safety functions are defined as fol-
lows:
ON: The state in which the relay contacts are closed or the transistor is ON and current
flows into the signal line.
OFF: The state in which the relay contacts are open or the transistor is OFF and no cur-
rent flows into the signal line.
EDM1
+
EDM1
−
8
7
0 V
CN8
24 V Power Supply
SERVOPACK
External Device
Type
Signal Name
Pin No.
State
Meaning
Output
EDM1
CN8-8
CN8-7
ON
The /HWBB1 signal and /HWBB2 signal are both operat-
ing normally.
OFF
Both the /HWBB1 signal and /HWBB2 signal are not
operating normally or either of the two is not operating
normally.
Items
Characteristics
Remarks
Maximum Allowable Voltage
30 VDC
−
Maximum Current
50 m ADC
−
Maximum Voltage Drop at ON
1.0 V
Voltage between EDM1+ to EDM1- when the current is
50 mA.
Maximum Delay Time
20 ms
Time from change of /HWBB1, /HWBB2 to change of
EDM1