6 (2) setting monitor factor, 3) related parameters – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual
Page 143

5 Adjustments
5.1.3 Monitoring Analog Signals
5-6
(2) Setting Monitor Factor
The output voltages on analog monitor 1 and 2 are calculated by the following equations.
(3) Related Parameters
Use the following parameters to change the monitor factor and the offset.
Analog monitor 1 output voltage = (-1)
×
Analog monitor 2 output voltage = (-1)
×
(Pn006=n.00
غغ
) (Pn552)
(Pn007=n.00
غغ
×
Multiplier + Offset voltage [V]
×
Multiplier + Offset voltage [V]
(Pn550)
(Pn551)
(Pn553)
Signal selection
Signal selection
Pn550
Analog Monitor 1 Offset Voltage
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
-10000 to 10000
0.1 V
0
Immediately
Setup
Pn551
Analog Monitor 2 Offset Voltage
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
-10000 to 10000
0.1 V
0
Immediately
Setup
Pn552
Analog Monitor Magnification (
×1)
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
-10000 to 10000
0.01 times
100
Immediately
Setup
Pn553
Analog Monitor Magnification (
×1)
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
-10000 to 10000
0.01 times
100
Immediately
Setup
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque