A.810:
Encoder Backup Error
(Detected on the encoder

side)
(Only when an absolute

encoder is connected.)

Alarm occurred when the power
to the absolute encoder was ini-
tially turned ON.

Check to see if the power was
turned ON initially.

Set up the encoder (Fn008).

The encoder cable was discon-
nected, and was connected again.

Check to see if the power was
turned ON initially.

Confirm the connection and set up
the encoder (Fn008).

The power from both the control

power supply (+5 V) and the bat-
tery power supply from the SER-
VOPACK is not being supplied.

Check the encoder connector bat-
tery or the connector contact status.

Replace the battery or take similar
measures to supply power to the
encoder, and set up the encoder
(Fn008).

An absolute encoder fault
occurred.

If the alarm cannot be reset by set-

ting up the encoder again, replace
the servomotor.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

A.820:
Encoder Checksum

Error

(Detected on the encoder

side.)

An encoder fault occurred.

Set up the encoder again using
Fn008. If the alarm still occurs, the
servomotor may be faulty. Replace
the servomotor.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

A.830:
Absolute Encoder

Battery Error
(The absolute encoder

battery voltage is lower
than the specified value.)

The battery connection is incor-
rect.

Check the battery connection.

Reconnect the battery.

The battery voltage is lower than
the specified value 2.7 V.

Measure the battery voltage.

Replace the battery.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

A.840:
Encoder Data Error
(Detected on the encoder
side.)

An encoder fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the servomotor may be
faulty. Replace the servomotor.

Malfunction of encoder because
of noise interference, etc.

Correct the wiring around the
encoder by separating the encoder
cable from the servomotor main cir-
cuit cable or by checking the
grounding and other wiring.

A.850:
Encoder Overspeed
(Detected when the con-
trol power supply was
turned ON.)
(Detected on the encoder
side.)

The servomotor was running at
200 min

-1

or higher when the

control power supply was turned
ON.

Check the speed monitor (Un000)
to confirm the servomotor speed
when the power is turned ON.

Reduce the servomotor speed to a
value less than 200 min

-1

, and turn

ON the control power supply.

An encoder fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the servomotor may be
faulty. Replace the servomotor.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be

faulty. Replace the SERVOPACK.

(cont’d)

Alarm:

Alarm Name

Cause

Investigative Actions

Corrective Actions