A.E72
*2
:
Feedback Option
Module Detection
Failure
The connection between the
SERVOPACK and the feedback
option module is faulty.
Check the connection between the
SERVOPACK and the feedback
option module.
Correctly connect the feedback
option module.
The feedback option module was
disconnected.
–
Execute Fn014 (Resetting configu-
ration error of option module) with
the digital operator or SigmaWin+
and turn the power supply OFF and
then ON again.
A feedback option module fault
occurred.
–
Replace the feedback option mod-
ule.
A SERVOPACK fault occurred.
–
Replace the SERVOPACK.
A.E73:
Unsupported Option
Module
A command option module fault
occurred.
–
Replace the command option mod-
ule.
A unsupported command option
module was connected.
Refer to the catalog of the con-
nected command option module.
Connect a compatible command
option module.
A.E74:
Unsupported Safety
Option Module
A safety option module fault
occurred.
–
Replace the safety option module.
A unsupported safety option
module was connected.
Refer to the catalog of the con-
nected safety option module.
Connect a compatible safety option
module.
A.E75
*2
:
Unsupported
Feedback Option
Module
A feedback option module fault
occurred.
–
Replace the feedback option mod-
ule.
A unsupported feedback option
module was connected.
Refer to the catalog of the con-
nected feedback option module or
the manual of the SERVOPACK.
Connect a compatible feedback
option module.
A.E80:
Command Option
Module Unmatched
Error
The command option module was
replaced with a different model.
–
Execute Fn014 (Resetting configu-
ration error of option module) with
the digital operator or SigmaWin+
and turn the power supply OFF and
then ON again.
A.EA2:
DRV Alarm 2
(SERVOPACK WDC
error)
The timing of synchronization
between the servomotor and
command option module changed
due to change in the communica-
tions cycle of the host controller
connected to the command option
module.
–
Turn the power supply OFF and
then ON again. If the alarm occurs
again, restart communications
processing from the host controller.
The connection between the
SERVOPACK and the command
option module is faulty.
Check the connection between the
SERVOPACK and the command
option module.
Correctly connect the command
option module.
A command option module fault
occurred.
−
Replace the command option mod-
ule.
A SERVOPACK fault occurred.
−
Replace the SERVOPACK.
A.Eb1:
Safety Function Signal
Input Timing Error
The lag between activations of
the input signals /HWBB1 and
/HWBB2 for the HWBB function
is 10 seconds or more.
Measure the time lag between the
/HWBB1 and /HWBB2 signals.
The host controller output signal
circuits or devices for /HWBB1 and
/HWBB2 or the SERVOPACK
input signal circuits may be faulty.
Alternatively, the input signal
cables may be disconnected. Repair
or replace them.
A.ED1:
Command Option
Module IF Command
Timeout Error
Processing of the sensor ON
command from the command
option module is not completed.
−
Input a servo ON command when
the motor is stopped.
Processing of the sensor ON
command from the command
option module is not completed.
−
Check that the encoder is connected
correctly and input a sensor ON
command when the motor is
stopped.
∗2. The alarm may occur when a fully-closed option module is mounted.
(cont’d)
Alarm:
Alarm Name
Cause
Investigative Actions
Corrective Actions