2.6 Selecting Peripheral Devices

2-11

2

2.6.2 Molded-case Circuit Breaker and Fuse Capacity

* 1. Nominal value at the rated load. The specified derating is required to select an appropriate

fuse capacity.

* 2. Cutoff characteristics (25

°

C): 300% five seconds min. and inrush current of 20ms.

* 3. A preventive circuit for inrush current is not built in the 24 VDC control power supply. The

protective circuit must be designed by the customer.

* 4. Make sure the current capacity is accurate. For the SERVOPACK with the cooling fan built-

in, an inrush current flows; 200 % of the current capacity in the table above for two seconds,
when turning ON the control circuit power supply to start the fan working.

Note: Do not use a fast-acting fuse. Because the SERVOPACK’s power supply is a capacitor

input type, a fast-acting fuse may blow when the power is turned ON.

The SGDH SERVOPACK does not include a protective grounding circuit. Install a ground-fault protector
to protect the system against overload and short-circuit or protective grounding combined with the molded-
case circuit breaker.

Main

Circuit
Power

Supply

SERVOPACK

Model

Power Supply

Capacity per

SERVOPACK

(kVA)

Current Capacity of the

Molded-case Circuit Breaker

and the Fuse (A

rms

)

∗1,∗2

(Refer to 6.8.7)

Inrush Current

Capacity

(kW)

SGDH-

Main Circuit

Power Supply

Control Cir-

cuit Power

Supply

Main Circuit

Power Supply

Control Cir-

cuit Power

Supply

Single-
phase
200 V

0.05

A5AE

0.25

4

0.13

63A

60A

0.10

01AE

0.40

0.20

02AE

0.75

0.40

04AE

1.2

8

Three-
phase
200 V

0.45

05AE

1.4

4

0.15

∗4

118A

60A

0.75

08AE

1.9

7

1.0

10AE

2.3

1.5

15AE

3.2

10

2.0

20AE

4.3

13

63A

3.0

30AE

5.9

17

5.0

50AE

7.5

28

67A

7.5

75AE

15.5

41

0.27

∗4

40A

Three-
phase
400 V

0.45

05DE

1.1

1.6

0.7

∗4

10A

(24 VDC)

∗3

1.0

10DE

2.3

3.4

1.5

15DE

3.2

4.6

2.0

20DE

4.9

7.1

20A

3.0

30DE

6.7

9.7

5.0

50DE

10.3

14.9

78A

7.5

75DE

15.4

22.3

1.2

∗4

20A

IMPORTANT