12 Appendix

12.4.3 Monitor Modes

12-40

12.4.3 Monitor Modes

The following list shows available monitor modes.

* Available for the software version 32 or later

Parame-

ter No.

Content of Display

Unit

Un000

Actual motor speed

mm/s

Un001

Input speed reference

mm/s

Un002

Internal force reference (Value for rated force)

%

Un003

Electrical angle 1 (16-bit decimal code)

number of pulses from the

phase-U (0

°)

Un004

Electrical angle 2 (Angle from 0 (zero) degree of phase-U)

deg

Un005

Input signal monitor

Un006

Output signal monitor

Un007

Input reference pulse speed (displayed only in position control mode)

mm/s

Un008

Error counter (amount of position error) (displayed only in position control
mode)

reference unit

Un009

Accumulated load rate (Value for the rated force as 100%: Displays effective
force in 10 s cycle.)

%

Un00A

Regenerative load rate (Value for the processable regenerative power as 100%:
Displays regenerative power consumption in 10 s cycle.)

%

Un00B

Power consumed by DB resistance
(Value for the processable power when dynamic brake is applied as 100%: Dis-
plays DB power consumption in 10 s cycle.)

%

Un00C

Input reference pulse counter (32-bit decimal code)
(displayed only in position control mode)

Un00D

Feedback pulse counter (32-bit decimal code)

Un010

Motor maximum speed setting upper limit or encoder output resolution setting
upper limit

100mm/s or

Pulse/scale pitch (Pn280)

Un011

Hall sensor signal monitor