Warning, 4) dc power supply input – Yaskawa SGDH Linear Sigma Series User Manual
Page 185

7.2 Wiring Main Circuit
7-21
7
(4) DC Power Supply Input
When using the main circuit power supply input of the SGDH SERVOPACK with DC power supply, use the fol-
lowing power supply and set the parameter Pn001.2 to 1. Also, read carefully to the following ‘Important’ sec-
tion.
1. Servomotor returns the regenerative energy to the power supply when regenerating. SERVOPACK does
not regenerate with DC power supply input specifications, so regenerate the energy on the power supply
side.
2. Take appropriate measures to ensure that a high charging current stays inside the SERVOPACK when
power is OFF.
(a) Main Circuit and Control Power Supply Input
The following shows the connection for the main power supply and the control power supply.
(b) Setting Parameters
• SGDH SERVOPACK is applicable for both AC and DC power supply input excluding 7.5-kW control power
supply input.
However, if the DC power supply input supplies a voltage without setting ‘1’ (for DC power supply input) in
the parameter Pn001.2, the SERVOPACK’s internal elements will burn and may cause fire or malfunction.
When using the SERVOPACK with DC power supply input, confirm the following setting of parameters.
WARNING
IMPORTANT
Terminal
Symbol
Name
Main Circuit Power
Supply Voltage
when AC Power
Supply input
Functions
1 or
Main circuit plus terminal
200 VAC
(SGDH-AE)
270 to 310 VDC
400 VAC
(SGDH-DE)
513 to 648 VDC
Main circuit minus terminal
Common to all models
0 V
L1C, L2C
Control power supply input
terminal
200 VAC
(SGDH-AE)
Single-phase 200 to 230 VAC +10%, -15% (50/
60Hz) or 270 to 310 VDC, without polarity,
excluding 7.5-kW control power supply input.
24V, 0V
400 VAC
(SGDH-DE)
24 VDC (
±
15%)
Parameter
Meaning
Pn001
n.0
Not applicable for main circuit DC power supply input: Input the AC power sup-
ply for the terminal L1, L2 or L3.
n.1
Applicable for main circuit DC power supply input: Input the DC power supply
between the terminal
and the terminal
1, or the terminal
and the termi-
nal .
• When changing the parameters, turn the power ON again for the necessity of the effective setting.