7 Wiring

7.5.5 DC Reactor for Harmonic Suppression

7-38

7.5.5 DC Reactor for Harmonic Suppression

(1) Reactor Types

The SERVOPACK has the DC reactor connection terminals for power supply harmonic suppression. However,
SERVOPACKs with capacity of 7.5 kW do not have these terminals. The type of DC reactor to be connected dif-
fers depending on the SERVOPACK capacity. Refer to the following table.

Note: Select a proper DC reactor for the input current to the SERVOPACK.

Refer to 2.6.2 Molded-case Circuit Breaker and Fuse Capacity for input current to each
SERVOPACK. For the kind of reactor, refer to 7.5.5 DC Reactor for Harmonic Suppres-
sion
.

(2) Connecting a Reactor

Connect a DC reactor as shown in the following diagram. The DC reactor is connected in series to the rectifier
circuit’s output side.

Note: 1. The SERVOPACK

1 and

2 terminals for the DC reactor are short-circuited before ship-

ment. Remove the lead wire between these two terminals and connect the DC reactor with SER-
VOPACK.

2. DC reactor is an option (Provided by customer).

Applicable

SERVOPACK Model

SGDH-

DC Reactor

Model

Reactor Specifications

Inductance (mH)

Rated Current (A)

Single-phase
200 V

A5AE

01AE

X5071

40.0

0.85

02AE

X5070

20.0

1.65

04AE

X5069

10.0

3.3

Three-phase
200 V

05AE

X5061

2.0

4.8

08AE
10AE
15AE

X5060

1.5

8.8

20AE
30AE

X5059

1.0

14.0

50AE

X5068

0.47

26.8

Three-phase
400 V

05DE

X5074

4.7

1.5

10DE

X5075

3.3

4.5

15DE
20DE

X5076

2.2

8.6

30DE
50DE

X5077

1.5

14.1

DC Reactor

SERVOPACK

DC reactor

Three-phase input

1

2