Yaskawa SGDH Linear Sigma Series User Manual
Page 204

7 Wiring
7.6.2 Connecting External Regenerative Resistors
7-40
(2) Specifications of Built-in Regenerative Resistor
If the amount of regenerative energy exceeds the processing capacity of the SERVOPACK, then install an exter-
nal regenerative resistor. The following table shows the specifications of the SERVOPACK’s built-in resistor and
the amount of regenerative power (average values) that it can process.
* 1. The average regenerative power that can be handled is 20% of the rated capacity of the
regenerative resistor built into the SERVOPACK.
* 2. The values in parentheses are for the optional JUSP-RA05 Regenerative Resistor.
* 3. The values in parentheses are for the optional JUSP-RA18 Regenerative Resistor.
Applicable SERVOPACKs
SGDH-
Specifications
of Build-in Resistor
Regenerative Power
Processed by Built-in
Resistor
∗1
(W)
Minimum
Allowable
Resistance
(
Ω)
Resistance
(
Ω)
Capacity
(W)
Single-phase
200 V
A5AE, -04AE
−
−
−
40
Three-phase
200 V
05AE to -10AE
50
60
12
40
15AE
30
70
14
20
20AE
25
140
28
12
30AE
12.5
140
28
12
50AE
8
280
56
8
75AE
(3.13)
∗2
(1760)
∗2
(350)
∗2
2.9
Three-phase
400 V
05DE to -15DE
108
70
14
73
20DE, -30DE
45
140
28
44
50DE
32
180
36
28
75DE
(18)
∗3
(880)
∗3
(180)
∗3
18
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 USB Copy Unit (2 pages)
- JVOP-181 (22 pages)
- SI-EN3 (54 pages)
- MECHATROLINK-III (35 pages)
- SI-ET3 (49 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)