beautypg.com

2 starting time and stopping time, 2 starting time and stopping time -13 – Yaskawa SGDH Linear Sigma Series User Manual

Page 111

background image

4.5 SERVOPACK Overload Characteristics and Allowable Load Mass

4-13

4

4.5.2 Starting Time and Stopping Time

The starting time tr and the stopping time tf of linear servomotor under constant load conditions can be calcu-
lated using the following formulas.

Calculate the motor force from the motor current: Motor force = Motor force constant

×

Motor effective current

The following figure shows the motor force and motor speed timing chart.

V

M

Motor movement speed (m/s)

M

Load mass including motor (kg)

F

PM

Motor instantaneous peak force (N) in combination with a SERVOPACK

F

L

Load force (N)

Starting time tr = [ s ]

M

x V

M

F

PM

F

L

M

x V

M

F

PM

+ F

L

Stopping time tf = [ s ]

Motor force
(Current amplitude)

Motor movement
speed

tr

tf

V

M

F

PM

F

PM

F

L

Time

Time