beautypg.com

Yaskawa SGDH Linear Sigma Series User Manual

Page 275

background image

9.6 Setting Common Basic Functions

9-31

9

9.6.2 Switching the Linear Servomotor Movement Direction

The movement direction of the linear servomotor can be switched without changing the reference pulse to the
SERVOPACK or the reference voltage polarity.
This causes the travel direction (+, -) of the motor to reverse. The output signal polarity such as encoder pulse
output and analog monitor signal from the SERVOPACK does not change.

The standard setting for “forward movement” is the linear scale counting up direction.

Parameter

Name

Reference

Forward Reference

Reverse Reference

Pn000

n.†††0

Standard setting
(CCW = For-
ward)
(Factory setting)

n.†††1

Reverse
Direction Mode
(CW = Reverse)

The direction of P-OT and N-OT change. For Pn000 = n.†††0 (standard setting), counterclockwise is P-OT. For Pn000
= n.†††1 (Reverse Direction Mode), clockwise is P-OT.

Analog monitor

Moves

in forward

direction

(CCW)

Motor movement speed

Phase B progression

Force reference

Encoder pulse divided output

PAO

PBO

Analog monitor

Phase A progression

Encoder pulse devided output

PAO

PBO

Moves

in reverse

direction

(CW)

Analog monitor

Phase B progression

Encoder pulse divided output

PAO

PBO

Moves in
reverse
direction
(CW)

Phase A progression

Analog monitor

Encoder pulse divided output

PAO

PBO

Move in

forward

direction

(CCW)