2 three-phase, 200 v main circuit, 2 three-phase, 200 v main circuit -9, Sgdh-ae servopack – Yaskawa SGDH Linear Sigma Series User Manual
Page 31

1.3 Examples of Servo System Configurations
1-9
1
1.3.2 Three-phase, 200 V Main Circuit
Regenerative
resistor
Noise filter
Molded-case
circuit breaker
(MCCB)
Magnetic
contactor
I/O signal cable
Power supply
Three-phase 200 VAC
R S T
Protects the power
supply line by shutting
the circuit OFF when
an overcurrent is
detected.
Eliminates external noise
from the power line.
Connect an external
regenerative resistor
to terminals B1 and B2
if the regenerative
capacity is insufficient.
Turns the servo
ON and OFF.
Install a surge
suppressor.
(Refer to 2.6.1.)
(Refer to 2.6.4.)
(Refer to 2.6.5.)
(Refer to
2.6.3.)
(Refer to 2.6.3.)
(Refer to 2.6.2.)
Connection cable for
digital operator
Connection cable for
personal computer
(Refer to 2.6.1.)
Linear servomotor with core
Linear scale
(To be provided by
users)
Encoder
cable
Main circuit cable for
linear servomotor
Serial converter unit
Connection cable for
serial converter unit
(Refer to 2.5.)
(Refer to 2.5.)
(Refer to 2.5.)
(Refer to 2.5.)
(Refer to 2.4.)
Personal computer
Host controller
L1
L2
L3
U
V
W
L1C
L2C
B1
B2
B3
1
2
C
N
3
C
N
1
C
N
2
MODE/SET
DATA/
CHARGE
POWER
YASKAWA
SERVOPACK
SGDH-
200V
*1
*3
*2
*3: To connect a DC reactor, refer to 7.5.5 DC Reactor for Harmonic
Suppression.
*1: The positive terminal for the main circuit is only available for use
in the three-phase (200 VAC, 7.5 kW) SERVOPACKs.
Do not use the positive terminals 1 or 2.
*2: Before connecting an external regenerative resistor to
the SERVOPACK, be sure to disconnect the lead between terminals
B2 and B3.
Digital
operator
(Refer to 2.6.1.)
SGDH-AE
SERVOPACK
Connection cable
for hall sensor