(3) Vibration Reduction Functions

* Pn40B is valid for the software version 32 or later.

Function Name and

Related Parameters

Description

Features

Valid

Control

Modes

Refer-

ence

Section

Soft Start

Pn305
Pn306

Converts a stepwise speed reference to a
constant acceleration or deceleration for
the specified time interval.

A constant acceleration/deceleration is
achieved for smoother operation. The
operation time is increased for the speci-
fied time.

Speed

9.7.4

Acceleration/

Deceleration Filters

Pn204
Pn207

A 1st-order delay filter for the position
reference input.

Enables smooth operation.
The reference time increases by the filter
delay time even after the reference input
has been completed.

Position

9.8.4

Movement Average

Filter

Pn207
Pn208

A movement averaging filter for the posi-
tion reference input.

Enables smooth operation.
The reference time increases by the filter
delay time even after the reference input
has been completed.

Position

9.8.4

Speed Feedback

Filter

Pn308

A standard 1st-order delay filter for the
speed feedback.

The feedback speed is smoother.
The response is delayed if a large value is
set.

Position
Speed

10.4.7

Speed Reference

Filter

Pn307

A 1st-order delay filter for the speed refer-
ence.

The speed reference is smoother.
The response is delayed if a large value is
set.

Speed

9.7.5

Force Reference

Filter

Pn401

A 1st-order delay filter for the force refer-
ence.

This filter is effective in essentially all
frequency bands.
The response is delayed if a large value
(low frequency) is set.

Position
Speed
Force

10.4.10

Notch Filter

Pn409

Pn40B*

Notch filters can be set for the force refer-
ence.

Mainly effective for vibration between
500 and 2,000 Hz.
Instability will result if the setting is not
correct.

Position
Speed
Force

10.4.10