4 (3) vibration reduction functions – Yaskawa SGDH Linear Sigma Series User Manual
Page 326

10 Adjustments
10.1.2 List of Servo Adjustment Functions
10-4
(3) Vibration Reduction Functions
* Pn40B is valid for the software version 32 or later.
Function Name and
Related Parameters
Description
Features
Valid
Control
Modes
Refer-
ence
Section
Soft Start
Pn305
Pn306
Converts a stepwise speed reference to a
constant acceleration or deceleration for
the specified time interval.
A constant acceleration/deceleration is
achieved for smoother operation. The
operation time is increased for the speci-
fied time.
Speed
Acceleration/
Deceleration Filters
Pn204
Pn207
A 1st-order delay filter for the position
reference input.
Enables smooth operation.
The reference time increases by the filter
delay time even after the reference input
has been completed.
Position
Movement Average
Filter
Pn207
Pn208
A movement averaging filter for the posi-
tion reference input.
Enables smooth operation.
The reference time increases by the filter
delay time even after the reference input
has been completed.
Position
Speed Feedback
Filter
Pn308
A standard 1st-order delay filter for the
speed feedback.
The feedback speed is smoother.
The response is delayed if a large value is
set.
Position
Speed
Speed Reference
Filter
Pn307
A 1st-order delay filter for the speed refer-
ence.
The speed reference is smoother.
The response is delayed if a large value is
set.
Speed
Force Reference
Filter
Pn401
A 1st-order delay filter for the force refer-
ence.
This filter is effective in essentially all
frequency bands.
The response is delayed if a large value
(low frequency) is set.
Position
Speed
Force
Notch Filter
Pn409
Pn40B*
Notch filters can be set for the force refer-
ence.
Mainly effective for vibration between
500 and 2,000 Hz.
Instability will result if the setting is not
correct.
Position
Speed
Force