beautypg.com

56 (2) filter-related parameters – Yaskawa SGDH Linear Sigma Series User Manual

Page 300

background image

9 Operation

9.8.4 Smoothing

9-56

(2) Filter-related Parameters

Pn204

Position Reference Acceleration/Deceleration Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 6400

(0.00 to 64.00 ms)

0.01 ms

0

Immediately

Pn208

Average Movement Time of Position Reference

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 6400

(0.00 to 64.00 ms)

0.01 ms

0

Immediately

„ IMPORTANT

When the position reference acceleration/deceleration time constant (Pn204) is changed, a value with no reference pulse input
and a position error of 0 will be enabled. To ensure that the setting value is correctly reflected, stop the reference pulse from the
host controller and input the clear signal (/CLR), or turn the servo OFF to clear the error.

This function provides smooth motor operating in the following cases. The function does not affect the travel distance (i.e., the
number of pulses).

• When the host controller that outputs a reference cannot perform acceleration/deceleration processing.
• When the reference pulse frequency is too low.
• When the reference electronic gear ratio is too high (i.e., 10

× or more).

The difference between the position reference acceleration/deceleration time constant (Pn204) and the position reference
movement averaging time (Pn208) is shown below.

Acceleration/Deceleration Filter

Average Movement Time Filter

Pn207=n.†††0

Pn207=n.†††1

Position

Position

100%

63.2%

36.8%

Pn204

Pn204

Before filter applied
After filter applied

Response waveform for stepwise input

t

100%

Pn208

Pn208

Before filter applied
After filter applied

Response waveform for stepwise input

t

Pn208

Before filter applied
After filter applied

Response waveform for ramp reference input

t

Pn208