2 servopacks, 2 servopacks -6, Sgdh – Yaskawa SGDH Linear Sigma Series User Manual
Page 28

1 Outline
1.2.2 SERVOPACKs
1-6
1.2.2 SERVOPACKs
(1) SGDH for 50 W to 5.0 kW
Connecting terminal of DC Reactor
For connecting a reactor, refer to 7.5.5 DC Reactor for Harmonic Suppression.
Refer to 2.3 SERVOPACK Model
Designations.
With the front cover open
SERVOPACK model
YASKAWA
YASKAWA
SERVOPACK
SGDH-
MODE/SET
CHARGE
POWER
DATA/
MODE/SET
DATA/
CHARGE
POWER
Panel display
5-digit, 7-segment LED used to display
SERVOPACK status, alarm status, and other
values when parameters are input.
Refer to 8.1.2 Key Names and Functions.
Panel operator
Charge indicator
Lights when the main circuit power supply is
ON and stays lit as long as the main circuit power
supply capacitor remains charged. Therefore,
do not touch the SERVOPACK even after the power
supply is turned OFF if the indicator is lit.
Main circuit power
supply terminals
Used for main circuit power supply input.
Refer to 7.2 Wiring Main Circuit.
Used for control power supply input.
Refer to 7.2 Wiring Main Circuit.
Control power supply terminals
Used to connect external regenerative resistors.
Refer to 7.6 Connecting Regenerative Resistors.
Regenerative
resistor connecting terminals
Refer to 7.2 Wiring Main Circuit.
Ground terminal
Be sure to connect to protect against electrical shock.
Servomotor terminals
Connects to the servomotor power line.
Refer to 7.2 Wiring Main Circuit.
CN5 Analog monitor connector
Used to monitor motor speed, force
reference, and other values through
a special cable.
Refer to 6.8.3 Cables for Analog Monitor or
10.5 Analog Monitor.
Front cover
Power ON indicator
Lights when the control power supply is ON.
Panel keys
Used to set parameters.
Refer to 8.1.2 Key Names and Functions.
Refer to 6.8.1 Cables for Connecting Personal
Computer and 6.8.2 Digital Operator.
CN3 Connector for personal computer monitoring
and digital operator
Used to communicate with a personal computer
or to connect a digital operator.
CN1 I/O signal connector
Used for reference input signals and
sequence I/O signals.
Refer to 7.4 Examples of I/O Signal Connections.
Nameplate (side view)
Indicates the SERVOPACK model and ratings.
Refer to 1.1.3 SERVOPACKs.
CN2 Encoder connector
Connects to the serial converter unit.
Refer to 7.3 Wiring Encoders.
INFO