12.2.2 Calculating the Regenerative Energy

12-8

If the above calculation determines that the amount of regenerative power (Wk) processed by the built-in
resistor is not exceeded, then an external regenerative resistor is not required.
If the amount of regenerative power that can be processed by the built-in resistor is exceeded, then install an
external regenerative resistor for the capacity obtained from the above calculation.
If the energy consumed by load loss (in step 2 above) is unknown, then perform the calculation using E

L

= 0.

When the operation period in regeneration mode is continuous, add the following items to the above calcula-
tion procedure in order to find the required capacity (W) for the regenerative resistor.

• Energy for continuous regeneration mode operation period: E

G

(joules)

Here, E

G

= V

MG

T

G

t

G

• V

MG

: Linear servomotor speed (m/s) for same operation period as above

• T

G

: Linear servomotor’s generated force (N) in continuous regenerative mode operation period

• t

G

: Same operation periods as above

• Energy consumed by a regenerative resistor: E

K

= E

S

-

(E

L

+ E

M

+ E

C

) + E

G

• Required capacity of regenerative resistor: W

K

= E

K

/ (0.2

×