beautypg.com

6 regenerative resistor, 6 regenerative resistor -22, D 6.8.6 – Yaskawa SGDH Linear Sigma Series User Manual

Page 150: Regenerative resistor fo, 1) models, 2) dimensional drawings

background image

6 Specifications and Dimensional Drawings of Cables and Peripheral Devices

6.8.6 Regenerative Resistor

6-22

6.8.6 Regenerative Resistor

(1) Models

The SERVOPACKs with a capacity of 7.5 kW do not have a built-in regenerative resistor.
The following regenerative resistor is required according to the SERVOPACK model.

(2) Dimensional Drawings

SERVOPACK Model

Regenerative Resistor

Model

Specifications

Allowable

Power Loss

SGDH-75AE

JUSP-RA05

3.13

Ω , 1760 W

350 W

SGDH-75DE

JUSP-RA18

18

Ω , 880 W

180 W

Units: mm (in)

Model

W

H

D

M1

M2

Approx. Mass

kg (lb)

JUSP-RA05

300

(11.81)

350

(13.78)

95

(3.74)

250

(9.84)

335

(13.19)

7

(15.43)

JUSP-RA18

220

(8.66)

350

(13.78)

92

(3.74)

180

(7.09)

335

(13.19)

4

(8.82)

H

M2

M1

Ground terminal (M4 screw)

4

×φ6 (φ0.24) Mounting holes

Protective cover

Cement resistor

Units: mm (in)

External terminals (M5 screws)

D

W

30 (1.18)