9.7 Operating Using Speed Control with Analog Reference

9-39

9

(1) Automatic Adjustment of the Speed Reference Offset

The automatic adjustment of reference offset (Fn009) cannot be used when a position loop has been formed with
a host controller. Use the speed reference offset manual adjustment (Fn00A) described in the next section for a
position loop.
The zero-clamp speed control function can be used to force the motor to stop while the zero speed reference is
given. Refer to 9.7.6 Using the Zero Clamp Function.

The speed reference offset must be automatically adjusted with the servo OFF.

Adjust the speed reference offset automatically in the following procedure.

IMPORTANT

Step

Display after

Operation

Digital

Operator

Panel

Operator

Description

1

Turn OFF the SERVOPACK, and input the 0-V reference voltage
from the host controller or external circuit.

2

Press the DSPL/SET or MODE/SET Key to select the utility
function mode.

3

Press the LEFT/RIGHT or UP/DOWN Key, or UP or DOWN
Key to select parameter Fn009.
*The digit that can be set will blink.

4

Press the DATA/ENTER Key once, or DATA/SHIFT Key for
more than one second. “rEF_o” will be displayed.

5

Press the DSPL/SET or MODE/SET Key.
The reference offset will be automatically adjusted.
When completed, “donE” will blink for about one second.

6

About one second later

After “donE” is displayed, “rEF_o” will be displayed again.

7

Press the DATA/ENTER Key once, or DATA/SHIFT Key for
more than one second to return to the Fn009 display of the utility
function mode.

SERVOPACK

Servo OFF

0-V force

reference

Host
controller

Linear servomotor

Slow movement
(Servo ON)

DSPL

SET

(DSPL/SET Key)

MODE/SET

(MODE/SET Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)

DSPL

SET

(DSPL/SET Key)

MODE/SET

(MODE/SET Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)