beautypg.com

42 (5) connecting regenerative resistors – Yaskawa SGDH Linear Sigma Series User Manual

Page 206

background image

7 Wiring

7.6.2 Connecting External Regenerative Resistors

7-42

(5) Connecting Regenerative Resistors

Do not touch the regenerative resistors because they reach high temperatures. Use heat-resistant, non-flam-
mable wiring and make sure that the wiring does not touch the resistors.

Refer to 6.6 SERVOPACK Main

Circuit Wire Size for connecting wire size when connecting an external regenerative resistor.

(a) SERVOPACKs with Capacities of 400W or Less

(b) SERVOPACKs with Capacities of 0.5 to 5.0 kW

IMPORTANT

Connect an external regenerative resistor between
B1 and B2 terminals.

Note: The user must provide the regenerative resis-

tor.

Disconnect the wiring between the SERVOPACK’s
B2 and B3 terminals and connect an external regen-
erative resistor between the B1 and B2 terminals.
The user must provide the regenerative resistor.

Note: Be sure to remove the lead wire between the

B2 and B3 terminals.

Enlarged View

YASKAWA SERVOPACK

SGDH-

MODE/SET

CHARGE

POWER

DATA/

L1C

L2C

B1

B2

U

V

W

Enlarged View

L1C

L2C

B1

B2

B3

U
V

YASKAWA SERVOPACK200V

SGDH-

MODE/SET

CHARGE

POWER

DATA/

YASKAWA