Getting Started ..............................................................................................2-1
General Preparation .......................................................................................2-1
To open the QC-5000 software ..............................................................2-1
To set machine zero ................................................................................ 2-2
To display the feature list ........................................................................2-2
To display the program template .............................................................2-3
To nest the template windows .................................................................2-4
Select the Active Probe ............................................................................2-5
To select the active probe ........................................................................2-5
Probing Technique ........................................................................................2-5
Good probing techniques ........................................................................2-5
Bad probing techniques ..........................................................................2-5
Recording the Quick Start Program ..............................................................2-6
Clearance moves .....................................................................................2-6
To insert a clearance move ......................................................................2-7
Creating the Start Point .................................................................................2-8
To record the quick start program ...........................................................2-8
To move the probe to the start point ....................................................... 2-9
Recording the Part View Window ............................................................... 2-10
To record the part view window display ................................................ 2-10
Creating the Datum .................................................................................... 2-11
To create the primary plane ................................................................... 2-11
Creating the Secondary Alignment .............................................................. 2-14
To create a secondary alignment ............................................................ 2-14
Creating the Zero Point ............................................................................... 2-17
To activate the VED probe group ......................................................... 2-17
To select a magnification ....................................................................... 2-18
To create an arc tool .............................................................................. 2-18
To re-size a VED probe tool .................................................................. 2-21
To create a zero point ............................................................................ 2-22
Save the Reference Frame ............................................................................ 2-30
To save the reference frame ................................................................... 2-30
To activate the contact probe group ...................................................... 2-31
Touch Probe Measurement .......................................................................... 2-32
To measure a circle ................................................................................ 2-33
Measuring 3-D Features .............................................................................. 2-36
To change the part view perspective ...................................................... 2-36
To measure a cone ................................................................................. 2-38
To measure a cylinder ........................................................................... 2-41
To measure a plane ............................................................................... 2-50
2-D Measurement with VED ...................................................................... 2-53
To change the part view perspective ...................................................... 2-53
To activate the VED probe group ......................................................... 2-55
To create a circle probe tool ................................................................... 2-56
To measure circle 3 ............................................................................... 2-59
To measure circle 4 ............................................................................... 2-61
To construct a bolt hole circle ............................................................... 2-64