Operator screens and menus – HEIDENHAIN IK 5394-3D User Manual
Page 546

A-2
Appendix A Profile measurement
Tolerances can be applied to profile measurements as bilateral or unilateral
pass/fail boundaries. Bilateral tolerances can be distributed equally or un-
equally around the nominal edges of the part, and are specified by the user.
The X, Y and angular offsets, the maximum form error, the number of data
points and tolerance pass/fail results can be displayed in the Measure Profile
window at the conclusion of the Fit operation. Upon completion of the
profile measurement the profile feature is created in the Features template.
Operator screens and menus
Functions for conducting profile measurements are located across the bot-
tom of the Measure Profile window. Functions for evaluating, displaying
and printing results are contained in the Measure Profile menu and in the
Measure profile toolbar. These functions are discussed in detail later in the
profile measurement operating instructions.
The Measure Profile window
The Measure Profile window contains functions for:
•
Allowing (or prohibiting) data shifts during profile fit analyses
•
Assigning measurement tolerances
•
Entering part data
•
Importing part data from the Features template
•
Removing the last point data entered
•
Initiating a fit analysis
•
Cancelling a fit measurement
•
Resetting the fit results and restoring data points
•
Selecting specific data
•
Accessing the Measure Profile menu
•
Completing the profile measurement