Datum setting with a touch probe, 6 w o rk piece set u p – HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual
Page 77
![background image](https://www.manualsdir.com/files/816464/content/doc077.png)
HEIDENHAIN iTNC 530
77
1
.6 W
o
rk
piece set
u
p
Datum setting with a touch probe
Insert the touch probe: In the MDI mode, run a TOOL CALL block
containing the tool axis and then return to the Manual Operation
mode
Select the probing functions: The TNC displays the
available functions in the soft-key row
Set the reference point at a workpiece corner, for
example: The TNC asks whether the prove points
from the previously measured basic rotation should
be loaded. Press the ENT key to load points
Position the touch probe at a position near the first
touch point of the side that was not probed for basic
rotation
Select the probing direction via soft key
Press NC start: The touch probe moves in the defined
direction until it contacts the workpiece and then
automatically returns to its starting point
Use the axis-direction keys to preposition the touch
probe to a position near the second contact point
Press NC start: The touch probe moves in the defined
direction until it contacts the workpiece and then
automatically returns to its starting point
Then the TNC shows the coordinates of the measured
corner point
Set to 0: Press the SET DATUM soft key
Press the END to close the menu