beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual

Page 510

background image

510

Manual operation and setup

14.8 D

a

tum set

ting with a t

o

uc

h pr

obe

Finding the angle between the angle reference axis and a
workpiece edge

Select the probe function by pressing the PROBING

ROT soft key

Rotation angle: If you need the current basic rotation

later, write down the value that appears under

Rotation angle

Make a basic rotation with workpiece edge to be

compared (see "Compensating workpiece

misalignment with a 3-D touch probe" on page 497)

Press the PROBING ROT soft key to display the angle

between the angle reference axis and the workpiece

edge as the rotation angle

Cancel the basic rotation, or restore the previous basic

rotation

Set the rotation angle to the value that you previously

wrote down

Measuring the angle between two workpiece edges

Select the probe function by pressing the PROBING ROT soft key

Rotation angle: If you need the current basic rotation later, write

down the displayed rotation angle

Make a basic rotation with first workpiece edge (see "Compensating

workpiece misalignment with a 3-D touch probe" on page 497)

Probe the second edge as for a basic rotation, but do not set the

rotation angle to zero!

Press the PROBING ROT soft key to display the angle PA between

the workpiece edges as the rotation angle

Cancel the basic rotation, or restore the previous basic rotation by

setting the rotation angle to the value that you wrote down

previously

PA

–10

100

a?

a?

L?

X

Z

Y

100