beautypg.com

18 .1 gener a l user par a met e rs – HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual

Page 604

background image

604

Tables and overviews

1

8

.1 Gener

a

l user par

a

met

e

rs

Rapid traverse for triggering touch probes

MP6150
1

to 300 000 [mm/min]

Pre-positioning at rapid traverse

MP6151

Pre-position with speed from MP6150: 0

Pre-position at rapid traverse: 1

Measuring center misalignment of the
stylus when calibrating a triggering touch
probe

MP6160

No 180° rotation of the touch probe during calibration: 0

M function for 180° rotation of the touch probe during calibration: 1 to 999

M function for orienting the infrared sensor
before each measuring cycle

MP6161

Function inactive: 0

Orientation directly through the NC: –1

M function for orienting the touch probe: 1 to 999

Angle of orientation for the infrared sensor

MP6162
0

to 359.9999 [°]

Difference between the current angle of
orientation and the angle of orientation set
in MP 6162; when the entered difference is
reached, an oriented spindle stop is to be
carried out

MP6163
0

to 3.0000 [°]

Automatic operation: Automatically orient
the infrared sensor before probing to the
programmed probing direction

MP6165

Function inactive: 0

Orient infrared sensor: 1

Manual operation: Compensate the probe
direction taking an active basic rotation into
account

MP6166

Function inactive: 0

Take basic rotation into account: 1

Multiple measurement for programmable
probe function

MP6170
1

to 3

Confidence range for multiple
measurement

MP6171
0.001

to 0.999 [mm]

Automatic calibration cycle: Center of the
calibration ring in the X axis referenced to
the machine datum

MP6180.0 (traverse range 1) to MP6180.2 (traverse range 3)
0

to 99 999.9999 [mm]

Automatic calibration cycle: Center of the
calibration ring in the Y axis referenced to
the machine datum

MP6181.x (traverse range 1) to MP6181.2 (traverse range 3)
0

to 99 999.9999 [mm]

Automatic calibration cycle: Upper edge of
the calibration ring in the Z axis referenced
to the machine datum

MP6182.x (traverse range 1) to MP6182.2 (traverse range 3)
0

to 99 999.9999 [mm]

Automatic calibration cycle: Distance below
the upper edge of the ring where the
calibration is carried out by the TNC

MP6185.x (traverse range 1) to MP6185.2 (traverse range 3)
0.1

to 99 999.9999 [mm]

Touch probes