beautypg.com

Storing measured values in the pallet preset table, E (see "storing measured values in the, 5 using t o uc h-pr obes – HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual

Page 493

background image

HEIDENHAIN iTNC 530

493

14.5 Using t

o

uc

h-pr

obes

Storing measured values in the pallet preset
table

Select any probe function

Enter the desired coordinates of the datum in the appropriate input

boxes (depends on the touch probe cycle being run)

Enter the datum number in the Number in table: input box

Press the ENTER IN PALLET PRES. TAB. soft key. The TNC saves

the datum in the preset table under the entered number

You use this function for determining pallet datums. This

function must be enabled by your machine tool builder.
In order to store a measured value in the pallet preset

table, you must activate a zero preset before probing. A

zero preset consists of the entry 0 in all axes of the preset

table!