2 machine switch-on – HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual
Page 61
![background image](https://www.manualsdir.com/files/816464/content/doc061.png)
HEIDENHAIN iTNC 530
61
1
.2
M
a
ch
in
e
s
w
it
ch
-o
n
1.2 Machine switch-on
Acknowledging the power interruption and
moving to the reference points
Switch on the power supply for control and machine. The TNC starts
the operating system. This process may take several minutes. Then
the TNC will display the message "Power interrupted" in the screen
header
Press the CE key: The TNC compiles the PLC program
Switch on the control voltage: The TNC checks
operation of the emergency stop circuit and goes into
the reference run mode
Cross the reference points manually in the displayed
sequence: For each axis press the machine START
button. If you have absolute linear and angle encoders
on your machine there is no need for a reference run
The TNC is now ready for operation in the Manual Operation mode.
Further information on this topic
Traversing the reference marks: See "Switch-on" on page 464
Operating modes: See "Programming and Editing" on page 85
Switch-on and crossing the reference points can vary
depending on the machine tool. Your machine manual
provides more detailed information.