Displaying calibration values

The TNC stores the effective length and radius, as well as the center

misalignment, for use when the touch probe is needed again. You can

display the values on the screen with the soft keys CAL. L and CAL. R.

Managing more than one block of calibrating
data

If you use several touch probes or measuring contacts arranged in a

cross shape on your machine, you must also use several blocks of

calibration data.
To be able to use more than one block of calibration data, you must set

Machine Parameter 7411=1. To find the calibration data, proceed in

the same way as is done with one single touch probe. When exiting

the Calibration menu, press the ENT key to confirm the entry of the

calibration data in the tool table and for the TNC to save the calibration

data in the tool table.
The TNC saves the calibration data in the following columns of the tool

table:

Effective ball tip radius (column R)

Center misalignment X: CAL-OF1

Center misalignment Y: CAL-OF2

Calibration angle: ANGLE

Averaged center misalignment (only effective for cycle 441): DR

The line of the tool table, to which the TNC saves the data, is

determined by the active tool number.

If you want to use several touch probes or calibration data

blocks: See "Managing more than one block of calibrating

data" on page 496.

Make sure that you have activated the correct tool number

before using the touch probe, regardless of whether you

wish to run the touch probe cycle in automatic mode or

manual mode.
If MP 7411=1 is set, the TNC shows the tool number and

name in the calibration menu.