Page 359: 3 fixt ur e monit or ing (dcm sof tw a re option)

background image

HEIDENHAIN iTNC 530

359

1

1

.3 Fixt

ur

e monit

or

ing (DCM

sof

tw

a

re

option)

Editing fixtures

Call the fixture management

Use the mouse or the arrow keys to select the fixture

that you want to edit. The TNC highlights the selected

fixture with color

To change the selected fixture, in the measurement

sequence

window the TNC shows the fixture

parameters that you can edit

Confirm removal with the YES soft key or cancel it

with NO

Removing fixtures

Call the fixture management

Use the mouse or the arrow keys to select the fixture

that you want to remove. The TNC highlights the

selected fixture with color

Remove selected fixture

Confirm removal with the YES soft key or cancel it

with NO

Only value input is editable. The position of the fixture on

the machine table cannot be corrected after placement. To

change the position of the fixture you have to remove it

first and then place it again!

Danger of collision!

If you remove a fixture, the TNC no longer monitors it,