beautypg.com

Exiting the pallet file, Executing the pallet file, Exiting the pallet file executing the pallet file – HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual

Page 461

background image

HEIDENHAIN iTNC 530

461

13.2 P

allet oper

ation with

t

o

ol-or

ient

e

d mac

h

ining

If the entries TO or CTO for all workpieces within a group contain the

status ENDED, the next lines in the pallet file are run.

Exiting the pallet file

Call the file manager: Press the PGM MGT key

Select a different type of file: Press the SELECT TYPE soft key and

the soft key for the desired file type, for example SHOW.H

Select the desired file

Executing the pallet file

Select the file manager in the Program Run, Full Sequence or

Program Run, Single Block operating modes: Press the PGM MGT

key

Display all type .P files: Press the SELECT TYPE and SHOW P. soft

keys

Select the pallet table with the arrow keys and confirm with ENT

To execute the pallet table: Press the NC Start button. The TNC

executes the pallets as set in MP7683

In mid-program startup, only one tool-oriented machining

operation is possible. Subsequent pieces are machined

according to the method entered.
The value entered in the CT-ID field is stored for a

maximum of 2 weeks. Within this time the machining

process can be continued at the stored location. After this

time the value is deleted, in order to prevent large

amounts of unnecessary data on the hard disk.
The operating mode can be changed after executing a

group of entries with TO or CTO.
The following functions are not permitted:

Switching the traverse range

PLC datum shift

M118

In MP7683, set whether the pallet table is to be executed

blockwise or continuously (see "General user parameters"

on page 602).
Provided that Machine Parameter 7246 is set so that the

tool usage test is active, you can monitor the tool service

life for all tools used in a pallet (see "Tool usage test" on

page 190).