HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual
Page 504
![background image](https://www.manualsdir.com/files/816464/content/doc504.png)
504
Manual operation and setup
14.8 D
a
tum set
ting with a t
o
uc
h pr
obe
Corner as datum—using points that were
already probed for a basic rotation
Select the probe function: Press the PROBING P soft
key
Touch points of basic rotation ?
: Press ENT to
transfer the touch point coordinates
Position the touch probe at a position near the first
touch point of the side that was not probed for basic
rotation
Select the probe direction by soft key
Probing: press the NC Start button
Position the touch probe near the second touch point
on the same workpiece edge
Probing: press the NC Start button
Datum:
Enter both coordinates of the datum in the
menu window, confirm with the SET DATUM soft
key, or write the values to a table (see "Writing the
measured values from touch probe cycles in datum
tables", page 491, or see "Writing the measured
values from touch probe cycles in the preset table",
page 492, or see "Storing measured values in the
pallet preset table", page 493)
To terminate the probe function, press the END key
Corner as datum—without using points that
were already probed for a basic rotation
Select the probe function: Press the PROBING P soft key
Touch points of basic rotation?
: Press NO ENT to ignore the
previous touch points. (The dialog question only appears if a basic
rotation was made previously.)
Probe both workpiece edges twice
Datum
: Enter the coordinates of the datum and confirm your entry
with the SET DATUM soft key, or write the values to a table (see
"Writing the measured values from touch probe cycles in datum
tables", page 491, or see "Writing the measured values from touch
probe cycles in the preset table", page 492, or see "Storing
measured values in the pallet preset table", page 493)
To terminate the probe function, press the END key
P
X=?
Y=?
X
Y
P
X
Y