beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual

Page 504

background image

504

Manual operation and setup

14.8 D

a

tum set

ting with a t

o

uc

h pr

obe

Corner as datum—using points that were
already probed for a basic rotation

Select the probe function: Press the PROBING P soft

key

Touch points of basic rotation ?

: Press ENT to

transfer the touch point coordinates

Position the touch probe at a position near the first

touch point of the side that was not probed for basic

rotation

Select the probe direction by soft key

Probing: press the NC Start button

Position the touch probe near the second touch point

on the same workpiece edge

Probing: press the NC Start button

Datum:

Enter both coordinates of the datum in the

menu window, confirm with the SET DATUM soft

key, or write the values to a table (see "Writing the

measured values from touch probe cycles in datum

tables", page 491, or see "Writing the measured

values from touch probe cycles in the preset table",

page 492, or see "Storing measured values in the

pallet preset table", page 493)

To terminate the probe function, press the END key

Corner as datum—without using points that
were already probed for a basic rotation

Select the probe function: Press the PROBING P soft key

Touch points of basic rotation?

: Press NO ENT to ignore the

previous touch points. (The dialog question only appears if a basic

rotation was made previously.)

Probe both workpiece edges twice

Datum

: Enter the coordinates of the datum and confirm your entry

with the SET DATUM soft key, or write the values to a table (see

"Writing the measured values from touch probe cycles in datum

tables", page 491, or see "Writing the measured values from touch

probe cycles in the preset table", page 492, or see "Storing

measured values in the pallet preset table", page 493)

To terminate the probe function, press the END key

P

X=?

Y=?

X

Y

P

X

Y