beautypg.com

3 fixt ur e monit or ing (dcm sof tw a re option) – HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual

Page 361

background image

HEIDENHAIN iTNC 530

361

1

1

.3 Fixt

ur

e monit

or

ing (DCM

sof

tw

a

re

option)

Set-up clearance

:

Setup clearance to the measuring point that the TNC

should maintain during pre-positioning. Input range

0 to 99999.9999

Tolerance

:

Maximum permissible deviation between nominal

and actual position of the respective test points. Input

range 0 to 99999.999. If the test point is out of

tolerance, the TNC issues an error message

Tool number/tool name

:

Tool number (or name) of the touch probe. Input

range 0 to 30000.9 if a number is entered; maximum

16 characters if a name is entered. If entering a tool

name, enter it between single quotation marks

Confirm the entries: The TNC generates the test

program, shows the name of the test program in a

pop-up window and asks whether you want to run the

test program

Answer with NO if you want to run the test program

later, and with YES if you want to run it now

If you have confirmed with YES, the TNC changes to

the Full Sequence mode and automatically selects

the generated program

Start the test program: The TNC prompts you to

manually pre-position the touch probe so that it is

located at clearance height. Follow the instructions in

the pop-up window

Start the measuring process: The TNC moves to each

test point one after the other. With a soft key you

specify the positioning strategy. Conform with NC

start each time

At the end of the test program the TNC displays a pop-

up window with the deviations from the nominal

position. If a test point is out of tolerance, the TNC

issues an error message in the pop-up window