Manual operation and setup

14.4 D

a

tum set

ting without a t

o

uc

h pr

obe

Basic rotations from the preset table rotate the coordinate

system about the datum, which is shown in the same line

as the basic rotation.
When setting a datum, the TNC checks whether the

positions of the tilting axes match the corresponding

values of the 3D ROT menu (depending on the setting in

the kinematics table). Therefore:

If the "Tilt working plane" function is not active, the

position display for the rotary axes must be = 0° (zero

the rotary axes if necessary).

If the "Tilt working plane" function is active, the position

displays for the rotary axes must match the angles

entered in the 3-D ROT menu.

The machine manufacturer can lock any lines in the preset

table in order to place fixed datums there (e.g. a center

point for a rotary table). Such lines in the preset table are

shown in a different color (default: red).
The line 0 in the preset table is write protected. In line 0,

the TNC always saves the datum that you most recently

set manually via the axis keys or via soft key. If the datum

set manually is active, the TNC displays the text MAN(0) in

the status display
If you automatically set the TNC display with the touch-

probe cycles for presetting, then the TNC does not store

these values in line 0.

Danger of collision!

Keep in mind that moving an indexing feature on your

machine table (realized by changing the kinematics

description) may also shift datums that are not directly

connected to the indexing feature.