3 fixt ur e monit or ing (dcm sof tw a re option) – HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual
Page 364

364
Programming: Special functions
1
1
.3 Fixt
ur
e monit
or
ing (DCM
sof
tw
a
re
option)
Loading fixtures under program control
You can also activate and deactivate saved fixtures under program
control. Proceed as follows:
Show the soft-key row with special functions
Select PROGRAM SPECIFICATIONS group
Scroll through the soft-key row
Enter the path and file name of the stored fixture and
confirm with the ENT key
Deactivating fixtures under program control
You can deactivate active fixtures under program control. Proceed as
follows:
Show the soft-key row with special functions
Select PROGRAM SPECIFICATIONS group
Scroll through the soft-key row
Select the reset function and confirm with the END
key
Stored fixtures are by default in the
TNC:\system\Fixture\Archive
directory.
Make sure that the fixture to be loaded has also been
saved with the active kinematics.
Make sure that no other chucking equipment is active
during automatic activation of a fixture. If necessary, make
prior use of the FIXTURE SELECTION RESET function.
You can also activate fixtures via the pallet tables in the
FIXTURE
column.