.3 Fixt

ur

e monit

or

ing (DCM

sof

tw

a

re

option)

Loading fixtures under program control
You can also activate and deactivate saved fixtures under program

control. Proceed as follows:

Show the soft-key row with special functions

Select PROGRAM SPECIFICATIONS group

Scroll through the soft-key row

Enter the path and file name of the stored fixture and

confirm with the ENT key

Deactivating fixtures under program control
You can deactivate active fixtures under program control. Proceed as

follows:

Show the soft-key row with special functions

Select PROGRAM SPECIFICATIONS group

Scroll through the soft-key row

Select the reset function and confirm with the END

key

Stored fixtures are by default in the
TNC:\system\Fixture\Archive

directory.

Make sure that the fixture to be loaded has also been

saved with the active kinematics.
Make sure that no other chucking equipment is active

during automatic activation of a fixture. If necessary, make

prior use of the FIXTURE SELECTION RESET function.
You can also activate fixtures via the pallet tables in the
FIXTURE

column.