HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual
Page 21
![background image](https://www.manualsdir.com/files/816464/content/doc021.png)
New functions in v
e
rsion 34049x
-07
HEIDENHAIN iTNC 530
21
Improvements to the global program settings (GS):
All the form data can now be set and reset under program control
(see "Technical prerequisites" on page 370)
Handwheel superimposition value VT can be reset when tool is
changed (see "Virtual axis VT" on page 378)
If the Swapping Axes function is active, it is now permitted to
position to machine-based positions on the axes that have not
been swapped
Improvements to the tool table TOOL.T:
Using the FIND ACTIVE TOOL NAMES soft key you can check
whether identical tool names are defined in the tool table (see
"Editing tool tables" page 178 ff)
The input range of the delta values DL, DR and DR2 have been
increased to 999.9999 mm (see "Tool table: Standard tool data"
The following additional functions are now available in the expanded
tool management (see "Tool management (software option)" on
Importing of tool data in CSV format (see "Importing tool data" on
Exporting of tool data in CSV format (see "Exporting tool data" on
Marking and deleting of selectable tool data (see "Deleting marked
Inserting of tool indices (see "Operating the tool management" on
New Cycle 225 ENGRAVING (see User’s Manual for Cycle
Programming)
New Cycle 276 CONTOUR TRAIN (see User’s Manual for Cycle
Programming)
New Cycle 290 INTERPOLATION TURNING (software option, see
User’s Manual for Cycle Programming)
In the thread milling cycles 26x a separate feed rate is now available
for tangential approach to the thread (see User’s Manual for Cycle
Programming)
The following improvements were made to the KinematicsOpt
cycles (see User’s Manual for Conversational Programming):
Newer, faster optimization algorithm
It is no longer necessary to run a separate measurement series for
position optimization after angle optimization
Return of the offset errors (change of machine datum) to the
parameters Q147-149
More plane measuring points for ball measurement
Rotary axes that are not configured are ignored by TNC when
executing the cycle