beautypg.com

18 .1 gener a l user par a met e rs – HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual

Page 605

background image

HEIDENHAIN iTNC 530

605

1

8

.1 Gener

a

l user par

a

met

e

rs

Radius measurement with the TT 130 touch
probe: Probing direction

MP6505.0 (traverse range 1) to 6505.2 (traverse range 3)

Positive probing direction in the angle reference axis (0° axis): 0

Positive probing direction in the +90° axis: 1

Negative probing direction in the angle reference axis (0° axis): 2

Negative probing direction in the +90° axis: 3

Probing feed rate for second measurement
with TT 130, stylus shape, corrections in
TOOL.T

MP6507

Calculate feed rate for second measurement with TT 130,

with constant tolerance: Bit 0 = 0

Calculate feed rate for second measurement with TT 130,

with variable tolerance: Bit 0 = 1

Constant feed rate for second measurement with TT 130: Bit 1 = 1

Maximum permissible measuring error
with TT 130 during measurement with
rotating tool

Required for calculating the probing feed rate in

connection with MP6570

MP6510.0
0.001

to 0.999 [mm] (recommended input value: 0.005 mm)

MP6510.1
0.001

to 0.999 [mm] (recommended input value: 0.01 mm)

Feed rate for probing a stationary tool with
the TT 130

MP6520
1

to 3000 [mm/min]

Radius measurement with the TT 130:
Distance from lower edge of tool to upper
edge of stylus

MP6530.0 (traverse range 1) to MP6530.2 (traverse range 3)
0.001

to 99.9999 [mm]

Set-up clearance in the tool axis above the
stylus of the TT 130 for pre-positioning

MP6540.0
0.001

to 30 000.000 [mm]

Clearance zone in the machining plane
around the stylus of the TT 130 for pre-
positioning

MP6540.1
0.001

to 30 000.000 [mm]

Rapid traverse for TT 130 in the probe cycle

MP6550
10

to 10 000 [mm/min]

M function for spindle orientation during
individual tooth measurement

MP6560
0

to 999

–1

: Function inactive

Measuring rotating tools: Permissible
rotational speed at the circumference of the
milling tool

Required for calculating rpm and probe feed

rate

MP6570
1.000

to 120.000 [m/min]

Measuring rotating tools: Permissible
rotational rpm

MP6572
0.000

to 1000.000 [rpm]

If you enter 0, the speed is limited to 1000 rpm

Touch probes