beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) ISO programming User Manual

Page 451

background image

HEIDENHAIN iTNC 530

451

13.2 P

allet oper

ation with

t

o

ol-or

ient

e

d mac

h

ining

PALPRESET

(entry optional):

Preset number from the pallet preset table. The TNC interprets the

preset number defined here as pallet datum (PAL entry in PAL/PGM

column). You can use the pallet preset to compensate mechanical

differences between the pallets. A pallet preset can also be

activated automatically when a pallet is added

PRESET

(entry optional):

Preset number from the preset table. The preset number defined

here is interpreted by the TNC either as a pallet datum (PAL entry in

the PAL/PGM column) or as a workpiece datum (PGM entry in the
PAL/PGM

line). If there is a pallet preset table active on your machine,

then use the PRESET column only for workpiece datums

DATUM

(entry optional):

Name of the datum table. The datum table must be stored in the

same directory as the pallet table. Otherwise you must enter the full

path name for the datum table. Datums from the datum table can be

activated in the NC program with Cycle 7 DATUM SHIFT

X, Y, Z

(entry optional, other axes also possible):

For pallets and fixtures, the programmed coordinates are referenced

to the machine datum. For NC programs, the programmed

coordinates are referenced to the pallet or fixture datum. These

entries overwrite the datum that you last set in the Manual mode of

operation. With the miscellaneous function M104 you can reactivate

the datum that was last set. With the actual-position-capture key,

the TNC opens a window that enables you to have the TNC enter

various points as datums (see table below):

Position

Meaning

Actual values

Enter the coordinates of the current tool position

referenced to the active coordinate system.

Reference

values

Enter the coordinates of the current tool position

referenced to the machine datum.

ACTL

measured

values

Enter the coordinates referenced to the active

coordinate system of the datum last probed in

the Manual operating mode.

REF

measured

values

Enter the coordinates referenced to the machine

datum of the datum last probed in the Manual

operating mode.