Workpiece setup 1.6 – HEIDENHAIN TNC 128 (77184x-02) User Manual
Page 59

Workpiece setup
1.6
1
TNC 128 | User's Manual HEIDENHAIN Conversational Programming | 5/2014
59
Datum setting with 3-D touch probe
(software option 17: Touch Probe Functions)
Insert a 3-D touch probe: In the
Positioning with Manual Data
Input mode, run a TOOL CALL block containing the tool axis and
then return to the
Manual Operation mode
Select the probing functions: The TNC displays the
available functions in the soft-key row
Select the function for setting the datum, e.g.
PROBE POSITION
Position the touch probe near the first touch point
on the first workpiece edge
Select the probing direction via soft key
Press NC start: The touch probe moves in the
defined direction until it contacts the workpiece
and then automatically returns to its starting point
Then the TNC displays the coordinates of the
measured position
To set to 0: Press the
SET DATUM soft key
Press the
END soft key to close the menu
Repeat this procedure for all axes, in which you want to set the
datum
Further information on this topic
Datum setting: see "Datum setting with 3-D touch probe (Touch
Probe Functions software option 17)", page 305