background image

Test run and program run

13.2 Showing the workpiece blank in the working space

13

328

TNC 128 | User's Manual HEIDENHAIN Conversational Programming | 5/2014

13.2

Showing the workpiece blank in the
working space

Application

In the

Test Run operating mode, you can graphically check the

position of the workpiece blank or reference point in the machine’s
working space and activate work space monitoring: Press the
BLANK IN WORKSPACE soft key to activate this function. You can
activate or deactivate the function with the

SW limit monitoring

soft key (2nd soft-key row).

A transparent cuboid represents the workpiece blank. Its
dimensions are shown in the

BLK FORM table. The TNC takes the

dimensions from the workpiece blank definition of the selected
program. The workpiece cuboid defines the coordinate system for
input. Its datum lies within the traverse-range cuboid.

For a test run it normally does not matter where the workpiece
blank is located within the working space. However, if you activate
working-space monitoring, you must graphically shift the workpiece
blank so that it lies within the working space. Use the soft keys
shown in the table.

You can also activate the current datum for the

Test Run operating

mode (see the following table).

Function

Soft keys

Shift workpiece blank in positive/negative
X direction

Shift workpiece blank in positive/negative
Y direction

Shift workpiece blank in positive/negative
Z direction

Show workpiece blank referenced to the
set datum

Switch monitoring function on or off

Note that even with

BLK FORM CYLINDER, a cuboid

is shown in the working space as workpiece blank.