beautypg.com

3 machine settings, External access, Tool usage file – HEIDENHAIN TNC 128 (77184x-02) User Manual

Page 349: Machine settings, Machine settings 14.3

background image

Machine settings 14.3

14

TNC 128 | User's Manual HEIDENHAIN Conversational Programming | 5/2014

349

14.3

Machine settings

External access

The machine tool builder can configure the external
access options. Refer to your machine manual. Refer
to your machine manual.

With the MOD function

External access you can grant or restrict

access to the TNC. If you have restricted the external access it
is no longer possible to connect to the TNC and exchange data
via a network or a serial connection, e.g. with the TNCremo data
transfer software.

Restricting external access:

In the MOD menu select the

Machine settings group

Select the

External access menu

Set the

EXTERNAL ACCESS ON/OFF soft key to OFF

Press the

OK soft key

Tool usage file

The tool usage test function must be enabled by
your machine manufacturer. Refer to your machine
manual. Refer to your machine manual.

With the MOD function

Tool usage file you can select whether the

TNC never, once, or always uses a tool usage file.

To generate a tool usage file:

In the MOD menu select the

Machine settings group

Select the

Tool usage file menu

Select the desired setting for the

Program Run, Full Sequence/

Single Block and Test Run operating modes
Press the

APPLY soft key

Press the

OK soft key