beautypg.com

Test run and program run 13.5 program run – HEIDENHAIN TNC 128 (77184x-02) User Manual

Page 338

background image

Test run and program run

13.5 Program run

13

338

TNC 128 | User's Manual HEIDENHAIN Conversational Programming | 5/2014

Example

The power failed while a thread cutting cycle in the tilted working
plane was being performed. You have to retract the tap:

Switch on the power supply for control and machine. The TNC
starts the operating system. This process may take several
minutes. Then the TNC will display the message "Power
interrupted" in the screen header

Activate the

Retraction mode: Press the RETRACT

soft key. The TNC displays the message

RETRACT.

Acknowledge the power interruption: Press the

CE

key. The TNC compiles the PLC program.

Switch on the control voltage: The TNC checks
the functioning of the EMERGENCY STOP circuit.
If at least one axis is not referenced, you have to
compare the displayed position values with the
actual axis value and confirm their agreement.
Follow the dialog, if required.

Check the preselected traversing mode: if required, select
THREAD

Check the preselected thread pitch: if required, enter the thread
pitch

Check the preselected direction of rotation: if required, select
the direction of thread rotation.
Right-handed thread: The spindle turns in clockwise direction
when moving into the workpiece and counterclockwise when
retracting
Left-hand thread: The spindle turns in counterclockwise
direction when moving into the workpiece and clockwise when
retracting

Activate retraction: Press the

RETRACT soft key

Retraction: Retract the tool with the machine axis keys or the
electronic handwheel
Axis key Z+: Retraction from the workpiece
Axis key Z-: Moving into the workpiece

Exit retraction: Return to the original soft-key level

End the

Retraction mode: Press the END

RETRACTION soft key. The TNC checks whether
the

Retraction mode can be ended. If necessary,

follow the dialog.

Answer the confirmation request: If the tool was not correctly
retracted, press the

NO soft key. If the tool was correctly

retracted, press the

YES soft key. The TNC hides the retraction

dialog.

Initialize the machine: if required, scan the reference points

Establish the desired machine condition: if required, reset the
tilted working plane