Information center configuration examples, Outputting log information to a unix log host, Network requirements – H3C Technologies H3C SecBlade NetStream Cards User Manual
Page 290: Configuration procedure

275
To do…
Use the command…
Remarks
Reset the log buffer
reset logbuffer
Available in user view
Reset the trap buffer
reset trapbuffer
Available in user view
Information center configuration examples
Outputting log information to a Unix log host
Network requirements
•
Send log information to a Unix log host with an IP address of 1.2.0.1/16;
•
Log information with severity higher than or equal to informational will be output to the log host;
•
The source modules are ARP and IP.
Figure 83 Network diagram for outputting log information to a Unix log host
Configuration procedure
Before the configuration, make sure that there is a route between SecBlade and PC.
1.
Configure the SecBlade
# Enable information center.
[SecBlade] info-center enable
# Specify the host with IP address 1.2.0.1/16 as the log host, use channel loghost to output log
information (optional, loghost by default), and use local4 as the logging facility.
[SecBlade] info-center loghost 1.2.0.1 channel loghost facility local4
# Disable the output of log, trap, and debugging information of all modules on channel loghost.
[SecBlade] info-center source default channel loghost debug state off log state off trap
state off
CAUTION:
As the default system configurations for different channels are different, you need to disable the output of
log, trap, and debugging information of all modules on the specified channel (loghost in this example)
first and then configure the output rule as needed so that unnecessary information will not be output.
Internet
PC
1.1.0.1/16
1.2.0.1/16
SecBlade
NSC
Device