23
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Create an NQA
operation and enter NQA
operation view.
nqa entry admin-name
operation-tag
By default, no NQA operation is created.
3.
Specify an NQA
operation type and enter
its view.
type { dhcp | dlsw | dns | ftp |
http | icmp-echo | path-jitter |
snmp | tcp | udp-echo |
udp-jitter | voice }
N/A
4.
(Optional.) Configure a
description.
description text
By default, no description is configured.
5.
(Optional.) Specify the
interval at which the NQA
operation repeats.
frequency interval
The default setting is 0 milliseconds. Only
one operation is performed.
If the operation is not completed when the
interval expires, the next operation does
not start.
6.
(Optional.) Specify the
probe times.
probe count times
By default, an NQA operation performs
one probe.
This command is not available for the path
jitter, UDP jitter, and voice operations.
Each of these operations performs only one
probe.
7.
(Optional.) Specify the
probe timeout time.
probe timeout timeout
The default setting is 3000 milliseconds.
This command is not available for the path
jitter, UDP jitter, and voice operations.
8.
(Optional.) Specify the
TTL for probe packets.
ttl value
The default setting is 20.
This command is not available for the
DHCP and path jitter operations.
9.
(Optional.) Specify the
ToS value in the IP packet
header of probe packets.
tos value
The default setting is 0.
10.
(Optional.) Enable the
routing table bypass
function.
route-option bypass-route
By default, the routing table bypass
function is disabled.
This command is not available for the
DHCP and path jitter operations.
11.
(Optional.) Specify the
VPN where the operation
is performed.
vpn-instance
vpn-instance-name
By default, the operation is performed on
the public network.
Configuring the collaboration function
Collaboration is implemented by associating a reaction entry of an NQA operation with a track entry.
The reaction entry monitors the NQA operation. If the number of operation failures reaches the specified
threshold, the configured action is triggered.
To configure the collaboration function: