RTM

RTM manages the creation, state machine, and execution of monitor policies.

EAA monitor policies

A monitor policy specifies the event to monitor and actions to take when the event occurs.
You can configure EAA monitor policies by using the CLI or Tcl.
A monitor policy contains the following elements:

One event.

At least one action.

At least one user role.

One running time setting.

For more information, see "

Elements in a monitor policy

."

Elements in a monitor policy

Event

Table 29

shows types of events that EAA can monitor.

Table 23 Monitored events

Event type Description

CLI

CLI event occurs in response to monitored operations performed at the CLI. For example,
a command is entered, a question mark (?) is entered, or the Tab key is pressed to
complete a command.

Syslog

Syslog event occurs when the information center receives the monitored log within a
specific period.

NOTE:

The log that is generated by the EAA RTM does not trigger the monitor policy to run.

Process

Process event occurs in response to a specific state change of the monitored process
(such as an exception, shutdown, start, or restart), regardless of whether the change is
caused by an automatic system task or a manual task performed from the CLI.

Hotplug

Hotplug event occurs when the monitored card is swapped while the device is
operating.

Interface

Interface event occurs when the monitored traffic statistic and a predefined threshold
match a condition.
Each interface event is associated with two user-defined thresholds: start threshold and
restart threshold. Policy execution is always triggered by crossing of the start threshold

and crossing of the restart threshold in turn.
EAA executes the monitor policy when the monitored statistic and the start threshold
meet a predefined condition, and then it executes the monitor policy again when the

monitored statistic and the restart threshold meet a predefined condition. This process

cycles for the monitor policy to be executed and re-executed.
For example, EAA executes the monitor policy when the monitored traffic statistic is

equal to the start threshold, and then it executes the monitor policy again when the
monitored traffic statistic is equal to or higher than the restart threshold.