beautypg.com

Log destinations, Default output rules for common logs, Default output rules for diagnostic logs – H3C Technologies H3C MSR 5600 User Manual

Page 214

background image

201

Table 14 Log levels

Severity

value

Level Description

0

Emergency

The system is unusable. For example, the system authorization has expired.

1 Alert

Action must be taken immediately. For example, traffic on an interface exceeds
the upper limit.

2 Critical

Critical condition. For example, the device temperature exceeds the upper limit,
the power module fails, or the fan tray fails.

3 Error

Error condition. For example, the link state changes or a storage card is
unplugged.

4 Warning

Warning condition. For example, an interface is disconnected, or the memory
resources are used up.

5 Notification

Normal but significant condition. For example, a terminal logs in to the device,
or the device reboots.

6 Informational

Informational message. For example, a command or a ping operation is
executed.

7 Debug Debug

message.

Log destinations

The system outputs logs to the following destinations: console, monitor terminal, log buffer, log host, and
log file. Log output destinations are independent and you can configure them after enabling the

information center.

Default output rules for common logs

A default common log output rule specifies the source modules and severity level of common logs that

can be output to a destination. Logs matching the output rule are output to the destination.

Table 21

shows the default output rules for common logs.

Table 15 Default output rules

Destination Log source modules

Output switch

Severity

Console All

supported

modules

Enabled informational

Monitor terminal

All supported modules

Disabled

informational

Log host

All supported modules

Enabled

Informational

Log buffer

All supported modules

Enabled

Informational

Log file

All supported modules

Enabled

Informational

Default output rules for diagnostic logs

Diagnostic logs can only be output to the diagnostic log file, and cannot be filtered by source modules

and severity levels.

Table 22

shows the default output rule for diagnostic logs.

This manual is related to the following products: