[Sysname] snmp-agent target-host trap address udp-domain 1.1.1.2 params securityname
public
# Create an RMON Ethernet statistics entry for Ethernet 1/1.
[Sysname] interface ethernet 1/1
[Sysname-Ethernet1/1] rmon statistics 1 owner user1
[Sysname-Ethernet1/1] quit
# Create an RMON event entry and an RMON alarm entry to send SNMP traps when the delta sample
for 1.3.6.1.2.1.16.1.1.1.4.1 exceeds 100 or drops below 50.
[Sysname] rmon event 1 trap public owner user1
[Sysname] rmon alarm 1 1.3.6.1.2.1.16.1.1.1.4.1 5 delta rising-threshold 100 1
falling-threshold 50 1 owner user1
NOTE:
1.3.6.1.2.1.16.1.1.1.4.1 is the object instance for Ethernet 1/1, where 1.3.6.1.2.1.16.1.1.1.4
represents the object for total incoming traffic statistics, and 1 is the RMON Ethernet statistics entry index
for Ethernet 1/1.
# Display the RMON alarm entry.
AlarmEntry 1 owned by user1 is VALID.
Sample type : delta
Sampled variable : 1.3.6.1.2.1.16.1.1.1.4.1
Sampling interval (in seconds) : 5
Rising threshold : 100(associated with event 1)
Falling threshold : 50(associated with event 1)
Alarm sent upon entry startup : risingOrFallingAlarm
Latest value : 0
# Display statistics for Ethernet 1/1.
EtherStatsEntry 1 owned by user1 is VALID.
Interface : Ethernet1/1
etherStatsOctets : 57329 , etherStatsPkts : 455
etherStatsBroadcastPkts : 53 , etherStatsMulticastPkts : 353
etherStatsUndersizePkts : 0 , etherStatsOversizePkts : 0
etherStatsFragments : 0 , etherStatsJabbers : 0
etherStatsCRCAlignErrors : 0 , etherStatsCollisions : 0
etherStatsDropEvents (insufficient resources): 0
Incoming packets by size :
64 : 7 , 65-127 : 413 , 128-255 : 35
256-511: 0 , 512-1023: 0 , 1024-1518: 0
# Query alarm events on the NMS. (Details not shown.)
On the device, alarm event messages are displayed when events occur. The following is a sample alarm
event message:
[Sysname]
#Aug 27 16:31:34:12 2005 Sysname RMON/2/ALARMFALL:Trap 1.3.6.1.2.1.16.0.2 Alarm table 1
monitors 1.3.6.1.2.1.16.1.1.1.4.1 with sample type 2,has sampled alarm value 0 less than(or
=) 50.