To do...

Use the command...

Remarks

Enable the error frame alarm

function

alarm oam error-frame enable

Optional

The system generates an error

frame alarm when the number of

error frames in a specific time

period (that is, the window size)

exceeds the corresponding

predefined threshold.

By default, this function is enabled.

Configure the window size and

threshold for error frame alarms

alarm oam error-frame

{ window

window

| threshold threshold } *

Optional

When the alarm threshold is set to

0, a lot of alarms are generated

immediately. Since alarm events

are carried in the OAM packets, a

lot of OAM packets are generated.

In this case, OAM packets may be

lost.

By default, the window size is 10

seconds, and the alarm threshold

is 20 frames.

Enable the error frame seconds

summary alarm function

alarm oam

error-frame-seconds-summary

enable

Optional

The system generates an error

frame seconds summary alarm

when the number of error frame

seconds (in an error frame second,

at least one error frame occurs) in

a specific time period (for example,

1 minute) exceeds the

corresponding predefined

threshold.

By default, this function is enabled.

Configure the window size and

threshold for error frame seconds

summary alarms

alarm oam

error-frame-seconds-summary

{ window window | threshold

threshold

} *

Optional

By default, the window size is 600

(in unit of 100 ms), and the alarm

threshold is 1 second.